Sign In | Join Free | My himfr.com
Home > Automated Perimetry Machine >

Fuse Type Automated Perimetry Test Machine 240V Multiple Report Analysis

Chongqing Bio Newvision Medical Equipment Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap Fuse Type Automated Perimetry Test Machine 240V Multiple Report Analysis from wholesalers
     
    Buy cheap Fuse Type Automated Perimetry Test Machine 240V Multiple Report Analysis from wholesalers
    • Buy cheap Fuse Type Automated Perimetry Test Machine 240V Multiple Report Analysis from wholesalers
    • Buy cheap Fuse Type Automated Perimetry Test Machine 240V Multiple Report Analysis from wholesalers
    • Buy cheap Fuse Type Automated Perimetry Test Machine 240V Multiple Report Analysis from wholesalers

    Fuse Type Automated Perimetry Test Machine 240V Multiple Report Analysis

    Ask Lasest Price
    Brand Name : SYSEYE
    Model Number : BIO-1000
    Certification : CE
    Price : $2,800.00-$3,200.00
    Payment Terms : T/T
    Supply Ability : `100
    Delivery Time : 5 working days
    • Product Details
    • Company Profile

    Fuse Type Automated Perimetry Test Machine 240V Multiple Report Analysis

    peripheral vision test machine beautiful software interface multiple report analysis


    BIO-1000 automatic computer vision instrument is developed by our R&D team to absorb the advantages of international advanced models. It integrates sound, light, mechanical and electrical technologies, adopts international general random detection mode for visual marking, and has a wide examination range (0-90°) to help doctors to judge the patient's eye condition more comprehensively.Automated Perimetry Machine Adopt the high-end computer configuration, compared with the domestic similar products, stability, reliability is higher.Support Windows XP, Win7 platform, beautiful software interface, simple operation, easy to learn and use.According to international standards, it provides a very comprehensive software testing program and multiple report analysis to assist in the diagnosis of diseases related to visual impairment and help to make a more accurate diagnosis

    Automated Perimetry Machine Specifications:

    Basic specification

    Provide multiple report analysis ​ Automated Perimetry Machine

    Inspection range

    90°

    Inspection distance

    30cm

    Background light brightness

    White 31.5asb

    Visual target brightness

    1asb--- -10000asb

    Visual target size

    GoldmannIII

    Visual target interval time

    200ms

    Visual target interval time

    Standard or adjustment according to patient reflection

    Threshold test model

    Center5-°16, center10° -68, 24 -2, 30-2, 30° -60° nasal step

    Upper Threshold test model

    30°- 40, 30°-76, P-60, 60°-81, 60°-120,190°-135 nasal side

    Special detection strategy

    Esterman monocular, Esterman binocular . user- customized test, 150P driver monocular fast detection, 150P driver monocular standard detection , upper 36 detection, blind spot detection,150horizontal straightness detection

    Pupil size test

    Automatic

    Fixation monitoring

    Blind spot monitoring , eye position eye position deviation alarm, eye deviation curve

    Environment light detection

    Automatic

    Analysis software

    Reliability analysis , single vision report, triple vision report, GPA half vision analysis, GPA glaucoma developing analysis , VFI vision index analysis

    Operation system

    Win7 above

    Feature

    Automated Perimetry Machine
    1. Comprehensive real-time monitoring, heiji-krakau physiological blind spot monitoring. Gaze tracking/head position tracking, automatic measurement of pupil diameter, reduce the impact of pupil effect on visual field detection.
    2. Personalized design, accurate clinical analysis, accurate and rapid examination strategy.
    3. Under international Goldman standard, providing a variety of calssic test procedures and report analysis.



    Background brightness and test stimulus brightness of the product are measured at the position of the pupil of the patient's eye.
    1.1 background brightness
    Background light: white with backlight intensity of 10 CD /m2.
    1.2 test stimuli are within the tolerance range specified in table 1.

    1Parameter of stimulus

    NO.ContentTolerance
    1Background light,Fuse Type Automated Perimetry Test Machine 240V Multiple Report AnalysisFuse Type Automated Perimetry Test Machine 240V Multiple Report Analysis+25%,-20%
    2Contrast ,Fuse Type Automated Perimetry Test Machine 240V Multiple Report AnalysisFuse Type Automated Perimetry Test Machine 240V Multiple Report AnalysisBackground white,stimulus whiteTolerance +25%,-20%
    3Stimulus position0°~10°:≤0.5°
    10°~30°:≤1°
    >30°:≤2°
    4Stimulus sizePoint angle:+20%,-15%
    5Interval time200ms, ±20%
    6Scope of backgroundMost of the peripheral stimulus points do not exceed 2° beyond the boundary
    7Stimulus shapeThe ratio of the short axis length to the long axis length of the stimulus points is shown in table 2